蘇州ABB伺服驅(qū)動器報警4007維修
4007 Resistance value is zero (_ecZERO_RESISTANCE_VALUE)
4007 Resistance value is zero (_ecZERO_RESISTANCE_VALUE)
For the selected motor the winding resistance is zero.To avoid this error, make sure that a motor has been selected from thedatabase in the Drive Setup Wizard. Alternatively, if a custom motor has been selected, check that the Measure motor
對于所選電機,繞組電阻為零。為避免此錯誤,請確保已從“驅(qū)動器安裝向?qū)А敝械臄?shù)據(jù)庫中選擇了電機;蛘撸绻x擇了自定義電機,請檢查測量電機。
resistance and inductance test has been selected and run using the Autotune tool.
resistance and inductance test has been selected and run using the Autotune tool.
轉(zhuǎn)載請注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動器維修,伺服電機維修
本文鏈接:http://www.9s7n.com/fuwu/Services_Show13481.htm
伺服驅(qū)動器維修 伺服電機維修 觸摸屏維修 變頻器維修
聯(lián)系方式:
電話:021-50157782
手機:13817011982 微信同號
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://www.9s7n.com
【 我們確保修好測試好給客戶。。!】